Voltage-drop testing the starter system can help you find unwanted electrical resistance that may prevent the engine from starting. Unwanted resistance is an obstacle to current flow.

High voltage drop can lead to:

  • Hard starts
  • No starts
  • Long-crank condition
  • No-crank condition
  • Sluggish, erratic or dead starter motor

High voltage drop, or unwanted resistance, can creep into a starter circuit in the form of:

  • corroded terminals or connections
  • loose or poor connections
  • carbon buildup in relay or solenoid contacts
  • worn or failed parts
  • damaged wires

Besides poor system maintenance, high temperatures and vibration in the starter circuit's operating environment can contribute to unwanted resistance.

The advantage of using voltage drops to check the starter circuit is that you don't have to remove components when trying to locate a bad part, wire, or connection.

To check for voltage drops, you'll need a digital multimeter. And, although the procedure is fairly simple, you may have to consult the repair manual for your particular vehicle make and model to help you locate, identify or gain access to wires and components during your test.

If you don't have the manual for your particular model, you can get a relatively inexpensive Haynes manual from Amazon. Haynes manuals come with step-by-step procedures and photos for many maintenance, repair and troubleshooting projects. So you'll get your small investment back in a short time.

Let's get started.

Index
I. Preparing to Test the Starting Circuit
II. Testing the Starter Ground Circuit
III. Testing the Starter Power Circuit
IV. Testing the Starter Control Circuit
Common Starter Circuit Voltage Drops
V. Effectively Ridding a Starter Circuit of Unhealthy Voltage Drops

Caution

The following tests require operating the starter motor. Follow the proper procedure to prevent the car from lurching forward and causing serious injuries.

Disable the fuel pump by removing the circuit fuse.
Disable the fuel pump by removing the circuit fuse. | Source

I. Preparing to Test the Starting Circuit

During the following tests, you need to operate the starter motor, but you don't want the engine to start. To do this, you can:

  • Disable the fuel system by removing the fuel pump fuse, OR
  • Disable the ignition system. To do this, unplug the ignition module, OR, if you have a distributor ignition system, unplug the high-tension ignition cable from the distributor cap and ground the cable with a jumper wire between the cable terminal and a clean engine surface, bracket or bolt.

If necessary, consult your vehicle repair manual to disable these systems.

Start by checking the starter ground circuit.
Start by checking the starter ground circuit. | Source

II. Testing the Starter Ground Circuit

The starter circuit is divided in three sections: the ground circuit, the power circuit, and the control circuit.

In this test, you'll check the ground side of the starter circuit to make sure there is no unusual resistance. Unusual voltage drops or unwanted resistance are more common on the ground side of a circuit. This is where current supplied to the starter returns to the battery.

Here, you are testing the connections between the starter motor and engine; engine and chassis; chassis and battery negative (-) post.

With the ignition and fuel systems disabled:

  1. Set the transmission to Park or Neutral.
  2. Apply the parking brake.
  3. Set your voltmeter to the lowest setting on the DC voltage scale.
  4. Connect your meter's positive (red) lead to the starter motor case.
  5. Connect your meter's negative (black) lead to the battery negative (-) post.
  6. Have an assistant turn the ignition key to the Start position to crank the engine for no more than 15 seconds.
  7. Check the readout on your meter.

Voltage drop on the ground side of the starter circuit should be no more than 0.2 volts. But some manufacturers will take a voltage drop reading between 0.2 and 0.6 as acceptable for the ground side of the starter circuit.

If you get a higher voltage drop reading, check the starter motor's mounting bolts for tightness. Make sure the battery negative terminal is tight and clean, as well as the battery-to-chassis connection.

A practical method to find the problem area in the circuit branch is to do a voltage drop test between:

  • The negative battery post and the engine.
  • The negative battery post and the chassis.
  • The negative battery post and the ground terminal to chassis.
  • The negative battery post and the negative cable terminal.

You'll need to crank the engine for each of these tests. Allow the starter to cool between tests for about two minutes to prevent damage to the starter.

Once you get a good voltage drop reading, most likely the problem will be in the section of the circuit you tested just before that.

Check for good starter circuit connections.
Check for good starter circuit connections. | Source

III. Testing the Starter Power Circuit

Here, you'll test the positive side for unusual voltage drop or unwanted resistance. This is also called the insulated circuit resistance test. You'll test the high current cables and connections that go from the battery positive side (+) to the starter motor.

  1. Set the transmission to Park (automatic) or Neutral (manual).
  2. Apply the parking brake.
  3. Set your voltmeter to the lowest setting on the DC Voltage scale.
  4. Connect the meter's positive (red) lead to the positive (+) post on the battery and the meter's ground (black) lead to the starter battery terminal.
  5. Have an assistant crank the engine for a few seconds, but no more than 15 seconds: just enough to get an accurate voltage reading.
  6. Check your meter's readout.

Your voltage drop reading should be no more than 0.5 Volts. But some manufacturers will take a voltage drop reading between 0.2 and 0.6 as acceptable for the positive side of the starter circuit.

If you get a higher reading, conduct a voltage drop on the terminals in that side of the circuit.

On starters with a top-mounted solenoid, check the voltage drop between:

  • The positive battery post and the battery terminal on the solenoid.
  • The positive battery post and its terminal.

When you get a good voltage drop reading (0.1 Volts or less), check the previous section of the circuit.

If you don't get a good reading, check the terminal connected to the battery post.

On starters with a remote-type solenoid (relay), check the voltage drop between:

  • The positive battery post and the terminal connected to the starter terminal on the relay.
  • The positive battery post and starter terminal on the relay.
  • The positive battery post and the battery terminal on the relay.
  • The positive battery post and the terminal that connects to the battery terminal on the relay.
  • Positive battery post and its terminal.

Your reading should be about 0.5 Volts or less on the power circuit; you shouldn't get a voltage drop higher than 0.1 across a terminal and cable, or any one-foot length of cable; and about 0.3 V across a switch (relay). Otherwise, you need to check the connections or the switch, make sure the connections are clean and tight; or replace the switch, if you suspect the internal contacts are bad.

Also, make sure there's no unwanted resistance in the starter control circuit.
Also, make sure there's no unwanted resistance in the starter control circuit. | Source

IV. Testing the Starter Control Circuit

If your ground and power circuit voltage drop tests didn't reveal any unusual resistance, test the starter control circuit.

Usually, components in the control circuit include the ignition switch, safety switch, and relay. These components can also succumb to wear, bad connections, corrosion or damage.

With the ignition and fuel system disabled:

  1. Set the transmission to Park or Neutral.
  2. Apply the parking brake.
  3. Set your voltmeter to the lowest setting on the DC voltage scale.
  4. Connect your meter's positive (red) lead to the positive battery post.
  5. Connect your meter's negative (black) lead to the starter switch terminal on the solenoid or relay. If you don't know where is the starter switch terminal, consult your vehicle repair manual. This terminal connects to the ignition switch you activate when you turn the ignition key to fire up the engine.
  6. Have an assistant turn the ignition key to the Start position to crank the engine for no more than 15 seconds.
  7. Check your meter's readout.

If your voltage reading is over 0.5 Volts, there's generally unwanted resistance on that part of the circuit. But your manufacturer may have another specification for this circuit. Consult your repair manual, if necessary.

To find the wire connection or component with high resistance, test wires and components in the circuit for voltage drop:

Check for voltage drop between:

  • The positive battery post and the starting safety switch (power output side first and then power input side).
  • The positive battery post and the relay (first the power output side and then the power input side).
  • The positive battery post and the ignition switch (power output side first and then power input side).

You want to gradually move closer to the battery power side as you test for voltage drop at each point in the circuit.

The last point checked after your meter shows normal voltage drop is where the problem is located. For example, if unwanted resistance shows on the power output side of your safety switch, but after checking the power input side of the safety switch you get a good reading, most likely your safety switch needs adjustment (usually on automatic transmissions) or replacement.

Gaining access to circuit components in not easy on many models. You can combine the previous method with specific voltage drop readings across any switch, relay, connector or length of wire when you can't trace voltage drop in a sequential order.

Consult your repair manual to locate and gain access to components and identify wires as necessary.

Common Starter Circuit Voltage Drops

Component
Voltage
Positive side
0.2 to 0.6 Volts
Ground side
less than 0.2 Volts
Across a length of wire
0.1 or 0.2 Volts
Connector
0.1 Volts
Across switch or relay
0.3 Volts
Keep your battery terminals clean and tight to avoid unwanted resistance.
Keep your battery terminals clean and tight to avoid unwanted resistance. | Source

V. Effectively Ridding a Starter Circuit of Unhealthy Voltage Drops

After making your repair, if any, confirm that your repair worked by retesting the part of the circuit that contained unwanted resistance. A bad, loose, or dirty connection is hard to spot just by looking at it and it will reintroduce unwanted resistance into the circuit. So, retest. It only takes a few minutes and you'll make sure the starter circuit will function properly.

You can also use other simple troubleshooting strategies described in this post on starting-system problems, and, as necessary, consult your repair manual to test specific components.

The following video shows you how to use voltage drop testing to find a bad connection (unwanted resistance) that is interfering with the starter circuit, preventing the engine from starting.

Questions & Answers

    © 2018 Dan Ferrell

    Comments

      0 of 8192 characters used
      Post Comment

      No comments yet.

      working

      This website uses cookies

      As a user in the EEA, your approval is needed on a few things. To provide a better website experience, axleaddict.com uses cookies (and other similar technologies) and may collect, process, and share personal data. Please choose which areas of our service you consent to our doing so.

      For more information on managing or withdrawing consents and how we handle data, visit our Privacy Policy at: https://axleaddict.com/privacy-policy#gdpr

      Show Details
      Necessary
      HubPages Device IDThis is used to identify particular browsers or devices when the access the service, and is used for security reasons.
      LoginThis is necessary to sign in to the HubPages Service.
      Google RecaptchaThis is used to prevent bots and spam. (Privacy Policy)
      AkismetThis is used to detect comment spam. (Privacy Policy)
      HubPages Google AnalyticsThis is used to provide data on traffic to our website, all personally identifyable data is anonymized. (Privacy Policy)
      HubPages Traffic PixelThis is used to collect data on traffic to articles and other pages on our site. Unless you are signed in to a HubPages account, all personally identifiable information is anonymized.
      Amazon Web ServicesThis is a cloud services platform that we used to host our service. (Privacy Policy)
      CloudflareThis is a cloud CDN service that we use to efficiently deliver files required for our service to operate such as javascript, cascading style sheets, images, and videos. (Privacy Policy)
      Google Hosted LibrariesJavascript software libraries such as jQuery are loaded at endpoints on the googleapis.com or gstatic.com domains, for performance and efficiency reasons. (Privacy Policy)
      Features
      Google Custom SearchThis is feature allows you to search the site. (Privacy Policy)
      Google MapsSome articles have Google Maps embedded in them. (Privacy Policy)
      Google ChartsThis is used to display charts and graphs on articles and the author center. (Privacy Policy)
      Google AdSense Host APIThis service allows you to sign up for or associate a Google AdSense account with HubPages, so that you can earn money from ads on your articles. No data is shared unless you engage with this feature. (Privacy Policy)
      Google YouTubeSome articles have YouTube videos embedded in them. (Privacy Policy)
      VimeoSome articles have Vimeo videos embedded in them. (Privacy Policy)
      PaypalThis is used for a registered author who enrolls in the HubPages Earnings program and requests to be paid via PayPal. No data is shared with Paypal unless you engage with this feature. (Privacy Policy)
      Facebook LoginYou can use this to streamline signing up for, or signing in to your Hubpages account. No data is shared with Facebook unless you engage with this feature. (Privacy Policy)
      MavenThis supports the Maven widget and search functionality. (Privacy Policy)
      Marketing
      Google AdSenseThis is an ad network. (Privacy Policy)
      Google DoubleClickGoogle provides ad serving technology and runs an ad network. (Privacy Policy)
      Index ExchangeThis is an ad network. (Privacy Policy)
      SovrnThis is an ad network. (Privacy Policy)
      Facebook AdsThis is an ad network. (Privacy Policy)
      Amazon Unified Ad MarketplaceThis is an ad network. (Privacy Policy)
      AppNexusThis is an ad network. (Privacy Policy)
      OpenxThis is an ad network. (Privacy Policy)
      Rubicon ProjectThis is an ad network. (Privacy Policy)
      TripleLiftThis is an ad network. (Privacy Policy)
      Say MediaWe partner with Say Media to deliver ad campaigns on our sites. (Privacy Policy)
      Remarketing PixelsWe may use remarketing pixels from advertising networks such as Google AdWords, Bing Ads, and Facebook in order to advertise the HubPages Service to people that have visited our sites.
      Conversion Tracking PixelsWe may use conversion tracking pixels from advertising networks such as Google AdWords, Bing Ads, and Facebook in order to identify when an advertisement has successfully resulted in the desired action, such as signing up for the HubPages Service or publishing an article on the HubPages Service.
      Statistics
      Author Google AnalyticsThis is used to provide traffic data and reports to the authors of articles on the HubPages Service. (Privacy Policy)
      ComscoreComScore is a media measurement and analytics company providing marketing data and analytics to enterprises, media and advertising agencies, and publishers. Non-consent will result in ComScore only processing obfuscated personal data. (Privacy Policy)
      Amazon Tracking PixelSome articles display amazon products as part of the Amazon Affiliate program, this pixel provides traffic statistics for those products (Privacy Policy)